Indesit BIAA series Manual rápido de servicio - Página 2
Navegue en línea o descargue pdf Manual rápido de servicio para Frigorífico Indesit BIAA series. Indesit BIAA series 2 páginas. Artica entry no frost fridge-freezer platform
También para Indesit BIAA series: Manual de instrucciones (12 páginas), Manual de instrucciones (8 páginas), Manual de instrucciones (48 páginas), Manual rápido de servicio (2 páginas)
THR3 No Frost Platform (Electronic Thermostat)
Procedura Autotest:
For 10 seconds, activation of FZ fan, defrost heating element and fridge light.
All loads off for 3 seconds.
Probe Check
If one of the two probes has a fault, the fridge light fl ashes for 5 seconds (1 second ON and 1
second OFF)
If everything is OK and there are no probe faults, the fridge light remains ON for 5 seconds.
All loads off for 3 seconds.
Defrost Heating Element Check
If there is a defrost heating element fault, the fridge light fl ashes for 5 seconds (1 second ON
and 1 second OFF).
If everything is OK and there is no defrost heating element fault, the fridge light remains ON
for 5 seconds.
All loads off for 3 seconds.
Electronic Board Check
If there is an electronic board fault, the fridge light fl ashes for 5 seconds (1 second ON and 1
second OFF).
If everything is OK and there is no electronic board fault, the fridge light remains ON for 5
seconds.
All loads off for 3 seconds.
Pause for 7 seconds.
Fridge Air Probe Check
If there is a fault relating to the FZ air probe, the fridge light fl ashes for 5 seconds (1 second
ON and 1 second OFF).
If everything is OK and there is no FZ air probe fault, the fridge light remains ON for 5 seconds.
All loads off for 3 seconds.
FZ Evaporator Probe Check
If there is a fault relating to the FZ evaporator probe, the fridge light fl ashes for 5 seconds (1
second ON and 1 second OFF).
If everything is OK and there is no FZ evaporator probe fault, the fridge light remains ON for 5
seconds.
All loads off for 3 seconds.
Activation of FZ fan and defrost heating element for 217 seconds.
2/2