Indesit BIAA series 서비스 퀵 매뉴얼 - 페이지 2
{카테고리_이름} Indesit BIAA series에 대한 서비스 퀵 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Indesit BIAA series 2 페이지. Artica entry no frost fridge-freezer platform
Indesit BIAA series에 대해서도 마찬가지입니다: 사용 설명서 (12 페이지), 사용 설명서 (8 페이지), 사용 설명서 (48 페이지), 서비스 퀵 매뉴얼 (2 페이지)
THR3 No Frost Platform (Electronic Thermostat)
Procedura Autotest:
For 10 seconds, activation of FZ fan, defrost heating element and fridge light.
All loads off for 3 seconds.
Probe Check
If one of the two probes has a fault, the fridge light fl ashes for 5 seconds (1 second ON and 1
second OFF)
If everything is OK and there are no probe faults, the fridge light remains ON for 5 seconds.
All loads off for 3 seconds.
Defrost Heating Element Check
If there is a defrost heating element fault, the fridge light fl ashes for 5 seconds (1 second ON
and 1 second OFF).
If everything is OK and there is no defrost heating element fault, the fridge light remains ON
for 5 seconds.
All loads off for 3 seconds.
Electronic Board Check
If there is an electronic board fault, the fridge light fl ashes for 5 seconds (1 second ON and 1
second OFF).
If everything is OK and there is no electronic board fault, the fridge light remains ON for 5
seconds.
All loads off for 3 seconds.
Pause for 7 seconds.
Fridge Air Probe Check
If there is a fault relating to the FZ air probe, the fridge light fl ashes for 5 seconds (1 second
ON and 1 second OFF).
If everything is OK and there is no FZ air probe fault, the fridge light remains ON for 5 seconds.
All loads off for 3 seconds.
FZ Evaporator Probe Check
If there is a fault relating to the FZ evaporator probe, the fridge light fl ashes for 5 seconds (1
second ON and 1 second OFF).
If everything is OK and there is no FZ evaporator probe fault, the fridge light remains ON for 5
seconds.
All loads off for 3 seconds.
Activation of FZ fan and defrost heating element for 217 seconds.
2/2