Indesit BIAA series Manuel de service rapide - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel de service rapide pour {nom_de_la_catégorie} Indesit BIAA series. Indesit BIAA series 2 pages. Artica entry no frost fridge-freezer platform
Également pour Indesit BIAA series : Manuel d'utilisation (12 pages), Manuel d'utilisation (8 pages), Manuel d'utilisation (48 pages), Manuel de service rapide (2 pages)

Indesit BIAA series Manuel de service rapide
THR3 No Frost Platform (Electronic Thermostat)
Procedura Autotest:
For 10 seconds, activation of FZ fan, defrost heating element and fridge light.
All loads off for 3 seconds.
Probe Check
If one of the two probes has a fault, the fridge light fl ashes for 5 seconds (1 second ON and 1
second OFF)
If everything is OK and there are no probe faults, the fridge light remains ON for 5 seconds.
All loads off for 3 seconds.
Defrost Heating Element Check
If there is a defrost heating element fault, the fridge light fl ashes for 5 seconds (1 second ON
and 1 second OFF).
If everything is OK and there is no defrost heating element fault, the fridge light remains ON
for 5 seconds.
All loads off for 3 seconds.
Electronic Board Check
If there is an electronic board fault, the fridge light fl ashes for 5 seconds (1 second ON and 1
second OFF).
If everything is OK and there is no electronic board fault, the fridge light remains ON for 5
seconds.
All loads off for 3 seconds.
Pause for 7 seconds.
Fridge Air Probe Check
If there is a fault relating to the FZ air probe, the fridge light fl ashes for 5 seconds (1 second
ON and 1 second OFF).
If everything is OK and there is no FZ air probe fault, the fridge light remains ON for 5 seconds.
All loads off for 3 seconds.
FZ Evaporator Probe Check
If there is a fault relating to the FZ evaporator probe, the fridge light fl ashes for 5 seconds (1
second ON and 1 second OFF).
If everything is OK and there is no FZ evaporator probe fault, the fridge light remains ON for 5
seconds.
All loads off for 3 seconds.
Activation of FZ fan and defrost heating element for 217 seconds.
2/2