4. Preliminary checks
Before giving power to the control unit, check all the connections carried out. Check particularly that there are no grazed cables, short circuits
between the wires and that all the accessories are connected to the terminal on the points indicated on the scheme at page 1.Once given power
supply check that:
1.
The led POWER is light on fix
2.
The inputs normally closed must have the correspondent led lighted on. The led must turn off itself when the contact of the input opens itself.
3.
Check that the radio module is connected and functioning
4.
Put the DIP 1 on ON
Check the connection of the motors following this procedure:
Note: during these handlings the photocells, the radio and the buttons ARE NOT active.
Dipswitch Position
5. Remote control learning
Memorize at least one 2-key remote control. During normal operation however, (i.e. not during programming) the 1st memorized key carries out the
step by step function (opening and closing of the gate), the 2° key handles courtesy light . The 3° ke y handles the pedestrian function (partial
opening).
Dipswitch position
Press the remote control's 1st key. The flashing
signal emits 2 flashes .
The remote control's 1st key is now memorized.
A
Press and release the RED button: The flashing
signal's LED is permanently lit.
Press the remote control's 2nd key. The flashing
signal emits 1 flash
The 2 buttons are now memorized and the
procedure ends. Repeat the procedure from
point « A » if you want to learn the button for the
courtesy light.
6-1622381
rev.2
04/02/2016
Press the RED key. The gate
must open. Adjust the eventual
opening limit switch.
Yes
Release the RED key and press
the BLUE one. The automation
must close. Bring it again on
close position.
Yes
Dipswitch Position
Press and release the RED
button: The flashing signal's
LED is permanently lit .
Yes
Yes
Yes
Yes
ITA
ENG
FRA
The automation does not move. Check
the wirings and repeat the test.
NO
The automation closes. Switch off the control unit
and invert the connections of the motor between
terminal pole A and B. Supply power again and
repeat the test.
The automation does not move. Check
NO
the wirings and repeat the test.
Check that the dipswitch 1 and
NO
2 are set OFF. repeat the test
If flashing signal has emitted 1 flash, the pressed key had
already been memorized and it is possible to continue with the
procedure. Otherwise, check that the remote control is working,
NO
that it has the same decoding settings of the control panel and
that the radio module is correctly inserted. Then repeat the test
Check that the dipswitch 1 and
NO
2 are set OFF. repeat the test
Check that the remote control works, that it has the same
decoding set in the control panel and that the radio mo-
NO
dule is inserted. Then repeat the test .
ESP