Shortening Scales

To shorten Digi Scale follow these steps:
The scale has stainless-steel wires pressed into the side that could be damaged if not
cut properly.
1. Clamp the wires so they do not pull away from the extrusion.
2. Using a hacksaw, cut through the aluminum extrusion.
3. Use a file or sanding tool to chamfer the cut end to approximately the
specifications shown in the illustration.
4. Remove all burrs.
5. Test the shortened scale by sliding a Encoder on. There should not be any
binding.
Wires
Accurate Technology Digi Scale
.07" (2mm)
.25" (6mm)
Wires