Siemens SIWAREX WL230 BB-S SA Manual de instrucciones - Página 30

Navegue en línea o descargue pdf Manual de instrucciones para Equipamiento industrial Siemens SIWAREX WL230 BB-S SA. Siemens SIWAREX WL230 BB-S SA 48 páginas. Base plate and elastomer bearing bb-s sa
También para Siemens SIWAREX WL230 BB-S SA: Manual (36 páginas), Manual de equipamiento (50 páginas), Manual de instrucciones (44 páginas)

Siemens SIWAREX WL230 BB-S SA Manual de instrucciones
Installation
5.2 Installing the base plate and elastomeric bearing
5.2.8

Install the load cell with elastomeric bearing unit

Safety guidelines
Death or serious bodily injury
A falling load bearing implement can lead to serious bodily injury or considerable material
damage depending on the potential risk.
Personal injuries, damage to the load cells
Insufficiently secured loads can fall and cause injuries or material damage. Therefore,
appropriate lifting tools must be used to lift the load bearing implement. The corresponding
safety regulations must be observed.
NOTICE
Damaging of load cells
Incorrect or incomplete installation can result in damage to the load cells, installed parts
and the load bearing implement.
Observe the warning notices at the start of the chapter, see: Safety information/instructions
(Page 23)
NOTICE
Damage of the load cells and the elastomeric bearing
• Check that the load cells and installation unit are installed correctly, e.g. by checking the
• Ensure that the cable does not become damaged or is cut off.
• Lay the cables through cable glands in the form of a vertical downwards loop to
Installation requirements
● Flatness of the mounting surfaces: The flatness of mounting surface planes must be
≤ 0.2 mm.
● Compressive strength of the mounting surfaces: The compressive strength of the
mounting surfaces has to be appropriate for the contact surface pressure of the base
plate and elastomeric bearing.
30
WARNING
CAUTION
mounting dimensions and oscillation distances. Incorrect assembly can result in damage
to the load cell and the installation unit.
discourage the penetration of water.
Operating Instructions, 03/2013, A5E31529044A-01
SB-S SA