When installing the sensor into the pipe it
is necessary to choose properly internal di-
ameter of the tube to ensure the inner walls
distances from the electrode to min. 5 mm.
In some cases (sticky liquids, liquids with low
dielectric constant) is suitable to mount the
sensor in the knee tube.
Applies to: CLS–23_–10, 11, 12, 20, 21
max.
min.
Fig. 4: Two state regulation by hysteresis setting
d
k
b
b
WRONG
d
WRONG
CORRECT
Fig. 5: Long fitting tubes in side wall mounting
8
>5
When installing the sensor in vertical position it can be used
for 2-state (LO-HI) level control between the min. and max.
level. The position of the minimum and maximum level can be
changed by setting the sensor. Fluid changes require new set-
tings of the sensor
E – Electrode length in mm
Applies to: CLS–23_–20, 30 (only for electrically non-conductive liquids)
>5
k
k
d
d
k
CORRECT
a
Fig. 3: Mounting in the pipe
b
Applies to: CLS–23_–21 (for electrically conductive liquids)
WRONG
Sensor installation close to inlet hole, in a narrow
neck or using improper welding flange may result in
malfunction of the sensor.
Suitable welding flanges can be found in the Dinel
assortment, types ON, NN – see Accessories.
a
a
a
>5
d
CORRECT
Applies to: All variants
CLS–23
© Dinel, s.r.o.
k