Ariston INTESA TP23 Manual del usuario, instrucciones de instalación y mantenimiento - Página 20

Navegue en línea o descargue pdf Manual del usuario, instrucciones de instalación y mantenimiento para Caldera Ariston INTESA TP23. Ariston INTESA TP23 50 páginas.

Installation

6.12 Fitting the Time Clock

To fit the mechanical time clock supplied with the boiler, it is nec-
essary to proceed as follows:
1) Remove the fastening screws 'A' from beneath the boiler;
2) Rotate the control panel forward, if necessary, it is possible to
lift the control panel up and rotate it to a fully horizontal posi-
tion;
3) Using a suitable knife, remove the knock out 'B' for the time
clock;
4) Insert the clock into the control panel;
5) Secure the clock in place using the four screw provided;
6) Remove the two screws 'C' and remove the cover to allow
access to the Printed Circuit Board;
7) Plug the clock cable into the connector on the Printed Circuit
Board and conect the cables to the clock as indicated in Fig.
6.21
1
A
2
3
Supplied By www.heating spares.co Tel. 0161 620 6677
A
B
20
4
5
6