Zanussi ZOG21317XK Manual del usuario - Página 21

Navegue en línea o descargue pdf Manual del usuario para Horno Zanussi ZOG21317XK. Zanussi ZOG21317XK 28 páginas.

Installation

WARNING!
Refer to Safety chapters.
Gas connection
WARNING!
Before the gas connection,
disconnect the mains plug from the
mains socket or deactivate the fuse
in the fuse box. Close the primary
valve of the gas supply.
The gas supply ramp is on the rear side of the
appliance.
WARNING!
Do not use rubber flexible pipes!
Do not fully put the oven into the built-in cabinet
(approximately 30 cm).
Connection with a flexible metallic pipe or
a rigid metallic pipe:
A
A. Gas supply ramp, end of shaft with ramp
B. Washer
C. Elbow
Put the supplied gasket between the pipe and
the gas supply ramp. Turn the pipe to the 1/2"
gas supply ramp.
1. Use a 22 mm spanner to tighten the nuts.
Keep the gas supply ramp in the correct
position. Do not apply force to the gas
supply circuit.
WARNING!
Do not use a flame to check for
leaks!
2. Fully move the oven into the built-in cabinet.
www.zanussi.com
B C
WARNING!
Do not squeeze the gas supply
ramp and the pipe when you
move the oven into the built-in
cabinet.
3. Seal the connection correctly. Use a leak
detection to control it.
Adjustment to different types of gas
Let only an authorized person do the
adjustment to different types of gas.
If the appliance is set for natural gas
you can change it to liquid gas, with
the correct injectors.
The gas rate is adjusted to suit.
WARNING!
Before you replace the injectors,
make sure that the gas knobs are in
the Off position. Disconnect the
appliance from the electrical supply.
Let the appliance cool down. There
is a risk of injury.
Oven injector replacement
1. Remove the bottom plate of the oven cavity
(A) to get access to the oven burner (B).
B
A
2. Release the screw (C), which keeps the
burner in position.
C
3. Carefully move the burner off the injector
support (D).
21