Support Triangles (2)
8. Slide the Camera Sub-assembly over the two pins located at the center of the
Common Crossbar Mount Support. There are three possible camera positions.
Choose the position which corresponds with the desired FOV. Some rocking
may be required to fully seat or unseat this assembly as the bushings and pins
are a precise fit.
9. Once the Camera Sub-Assembly is located on the pins and is flush with the
Common Crossbar Mount Support, place two aluminum thumbscrews into the
appropriate holes (marked by red circles in Figure 2.5) and tighten by hand.
10. Attach a trigger box cable and firewire cable to each camera. Secure them to
the top of the Common Crossbar Mount Support using the supplied Velcro strap
as shown in Figure 2.5.
Page 10 of 19
Figure 2.4 DIC AXP Carriage Support Assembly
Warning: Plugging or unplugging the 1394b firewire
cables while power is on can potentially damage 1394b
firewire devices.
40-5000-01500 Rev. A
DIC User Manual
Common Crossbar
Mount Support
Aluminum
Thumbscrews
(3) on Each Side
Glide Rails (2)