CommScope TDUX-75 Instructions d'installation

Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} CommScope TDUX-75. CommScope TDUX-75 4 pages. Inflatable duct seal for telephone cable ducts

TC-314-IP
Rev A, Feb 2017
www.commscope.com
Selection table
(dimensions in mm/inches)
Maximum cable diameter for duct with 1
cable or sum of 2 cables.
Product description
Duct
Ø
TDUX-35
mm
inch
mm
inch
125
4.9
120
4.7
115
4.5
110
4.3
105
4.1
100
3.9
95
3.7
90
3.5
85
3.3
80
3.1
75
2.9
70
2.8
65
2.7
60
2.4
55
2.2
50
2.0
45
1.8
40
1.6
35
1.4
25
1.0
30
1.2
19
0.7
25
1.0
12
0.5
* Note: in case 3 or more cables have to be sealed, the cable bundle diameter needs to be determined. Substract 5 mm/0.2 inches for each
clip used from max. cable diameter shown in table, to determine the max. cable bundle diameter. TDUX-clips must be ordered as a separate item.
TDUX-CL clips are not to be used with TDUX-35. They are applicable to TDUX-45 and larger. TDUX-35 is suitable for use in vacant ducts or ducts
with 1 cable.
1 Safety rules
Lubricant
Protect from frost. In case of eye contact, flush with clean water during 15 minutes, holding eyelids open. Seek medical attention if irritation persists.
Wash with mild soap and water if skin irritation occurs.
Gas cylinders
If the carbon dioxide gas cylinders are used to inflate TDUX, following safety rules should be considered. The gas pressure in the cylinder is approxi-
mately 60 bar (900 p.s.i.) at room temperature. Max. operational temperature is 50°C/122°F. Keep cool and dry. Use only as instructed in ope-
rating manual of TDUX-IT-16 inflator. Misuse can be dangerous. Do not handle the cylinder with unprotected hands
immediately after filling a TDUX duct seal. Frostbite can result.
TDUX seals
Do not inflate TDUX outside a duct.
2 Application
TDUX will seal ducts with/without cable(s) and can be installed even while water is flowing out of the duct. Avoid exposure of the installed TDUX
duct seal to direct sunlight.
3 Unit packaging
TDUX duct seals are packed per 10 pcs/box (TDUX-35: 25 pieces per box), including 1 lubricant disperser and 1 installation instruction.
Inflatable duct seal for telephone cable ducts
Each TDUX size will seal vacant ducts for the
duct range shown in the table.
TDUX-45
TDUX-60
TDUX-75
mm
inch
mm
inch
mm
56
46
40
45
1.8
30
38
1.5
28
30
1.2
32
1.3
18
0.7
27
1.1
18
0.7
TDUX
I N S T A L L A T I O N
TDUX-90
TDUX-100
inch
mm
inch
mm
inch
90
3.5
85
3.3
83
3.3
80
3.1
76
3.0
74
2.9
70
2.8
66
2.6
62
2.4
60
2.4
54
2.1
52
2.0
2.2
50
2.0
45
1.8
1.8
42
1.6
1.6
30
1.2
1.2
22
0.9
1.1
I N S T R U C T I O N
To seal 3 or more cables,
TDUX-125
use TDUX-CL clip (*)
mm
inch
Clip size
103 4.0
95
3.7
TDUX-CL-80
91
3.6
83
3.3
TDUX-CL-60
TDUX-CL-40
TDUX-CL-20