Dremel 3D40 Idea Builder Instructions
WARNING
Read the Dremel 3D40 manual and these
instructions before replacing the level-
ing servo motor in your Dremel 3D40. Failure to comply
with the warnings and instructions may result in fire,
equipment damage, property damage, or personal injury.
Always unplug Dremel 3D40 from its power before per-
forming any service procedures. Failure to do so may re-
sult in personal injury and equipment damage.
Use only Dremel approved materials and components.
Use of object materials, or 3D objects other than Dremel ap-
proved object materials and genuine Dremel components
may void warranty.
Repairs on the Dremel 3D40 may require the use of special
tools (pulling devices and bearing press). Authorized repair
centers have trained repair technicians and equipment nec-
essary to perform these repairs.
CAUTION
Use proper anti-static precautions when
performing this replacement. Discharge
static electricity before beginning. Work on a static-free sur-
face.
This document will outline the steps necessary to replace a
defective or damaged leveling assembly. This includes the
leveling switch, servo motor, and mounting bracket.
Figure 1: Replacement levelling servo motor assembly
Dremel 3D40 – Replacing the
leveling servo motor assembly
For the location of the repair center near you, please call 1-
844-4DRML3D (1-844-437-6533) Monday thru Friday, 8AM
to 6PM CST. Or, look on our web site at www.Dremel3D.com
and follow the link for 'Support'.
CONTINENTAL UNITED STATES
Dremel Service Center
4915 21st Street
Racine, WI 53406
Phone: 1-844-4DRML3D
SERVICE
Tools Required:
• 2mm Hex wrench (Allen key)
• T10 Torx (star) screwdriver bit
• Scissors
Step 1: Bring Printer to Safe State for Service
1. Turn on the printer, and verify that the temperature icon
reads cool (blue). If it is not blue, allow adequate time for
the nozzle to cool until the icon reads blue.
Figure 2: Home Screen (see encircled nozzle temperature)
2. Turn off the printer.
3. Unplug the printer.