Daintree GE current Lumination LPL Gen D Series Manuel d'installation - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Daintree GE current Lumination LPL Gen D Series. Daintree GE current Lumination LPL Gen D Series 4 pages. Led luminaire
Lumination
LPL Gen D Series
®
Electrical Connections - Sensor version
Sensor enclosure cover
Remove sensor enclosure cover. Carefullyremove knockout for AC mains input wires. Install UL listed electrical fttings in
1
the knockout holes for wire protection.
LPL22x
Connect the AC mains to the black (line) and white (neutral) input wires of the LED driver by using UL listed connectors or wire-nuts
for 18-14 AWG.
LPL24x
Connect the AC mains to the brown (line) and blue (neutral) input wires of the LED driver by using UL listed connectors or wire-nuts
for 18-14 AWG.
Connect the ground wire to the green-yellow ground wire of luminaire. When connecting dimming controller, wires must run
through a separate knockout hole equipped with an appropriate wire restraint or cable gland. Then, re-attach and fix enclosure cover
with screw by screw driver.
Line
Black (or Brown)
Neutral
White (or Blue)
Ground
Green/Yellow
www.gecurrent.com
© 2020 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
IND676
REV-A
AC mains
AC Mains
Installation Guide
4