5.1 Fitting oil recycling device
9. Setting the Synchronizer
The oil recycling device collects the oil in the oil
sump and returns it by apump to the oil circuit.
–
Wrap intake filter 3 of the oil recycling device
by the felt and fasten it to the oil sheet by the
clamp 2.
–
Install the oil hose 1 and secure it so that it
cannot get into contact with mobile parts.
1
ATTENTION !
Change the oil every 2 years, irrespective of the
number of operating hours.
The machine positions are seen by the
synchronizer in steps (increments) of 0.7° and
shown in the display. A complete revolution
corresponds to 512 steps.
1st Position
The machine should stop when the hook has
securely taken up the loop.
This means that the needle should raise above its
lower dead center until the hook tip has moved
approx. 6 mm above the needle to the left. This
corresponds to the increment number 50.
2nd Position
Needle bar a little bit before the upper dead center.
This corresponds to the increment number 190.