Duerkopp Adler 195 Manuel d'installation - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Duerkopp Adler 195. Duerkopp Adler 195 14 pages.
Également pour Duerkopp Adler 195 : Manuel d'utilisation (18 pages)

Duerkopp Adler 195 Manuel d'installation

6. Making the Plug Connections to the Motor Control,

Attaching the Synchronizer (Only Positioning Drive)
1
Fold over the machine
Connect the voltage compensation lead 1 to
the head.
If supplied, connect the external control panel.
Lay the wiring for buttons, control panel and, if
supplied, sewing light in the head cable duct.
Attention!
Before installing the synchronizer, switch off
the thread trimmer function on the control
panel.
With the machine switched off, push the
synchronizer onto the handwheel so that its
groove catches over the mounting pin on the
belt guard.
Arrest the handwheel in position A.
Screw on the synchronizer.
Position the marking 2 directly opposite the
notch 3.
This is position "0", the dependent initial
position for all machine position settings made
at the factory.
For setting the 1st and 2nd needle positions
see Section 9.
2
3
11