AudioCodes MP-100 Manuel de démarrage rapide - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} AudioCodes MP-100. AudioCodes MP-100 17 pages.

AudioCodes MP-100 Manuel de démarrage rapide
AudioCodes™ MP-100/104 Gateway Quick Start Installation Guide
March 2004
4.
Page 10 of 17
Quick Setup: Configure the Quick Setup field, as described below.
IP Address: Enter the IP address of the MP-104.
Subnet Mask: Enter the subnet mask of the MP-104.
Default Gateway Address: Enter the default gateway address if you are using a
static IP address or need to change the subnet mask or gateway address. Ensure
these match those on the IPRC Device Configuration page if using static IP
addressing.
DNS Primary Server IP: Should be set to 255.255.255.255.
DNS Secondary Server IP: Should be set to 255.255.255.255.
Control Protocol Type: Should be set to MGCP.
Call Agent IP: Should match the IPRC IP address.
Call Agent Port: Should be set to 2427.
Call Agent Domain Name: Leave this field blank.
Gateway Name: Enter the name to identify this gateway on the network, such as
MP104v4.2 (case-sensitive with no spaces or special characters). The default name
is set to the IP address of the MP-104 (e.g., [172.17.112.61]).
NOTE:
With a v8.x firmware IPRC, ensure the names match those in Axxess Data-
base Programming (under System\Cabinets\IPRC (32-Device)\Devices\MGCP
Gateway and Endpoint).
Endpoint Name: The default endpoint name is "ACgw" (case-sensitive) and
should not be changed to avoid hostname resolution complications. Each endpoint
has a number appended to it. For example, line 1 is assigned the name "ACgw0,"
line 2 is "ACgw1," and line 4 is "ACgw3."
NOTE:
With a v1.x firmware IPRC, ensure the names match those on the MGCP
Endpoint Name Settings page in the IPRC Web page. With a v8.x firmware IPRC,
ensure the names match those in Axxess Database Programming (under Sys-
tem\Cabinets\IPRC (32-Device)\Devices\MGCP Endpoint).
To restart the system, click RESET.