4RF Aprisa SR+ Manuel - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} 4RF Aprisa SR+. 4RF Aprisa SR+ 12 pages. Demo kit
Également pour 4RF Aprisa SR+ : Manuel de démarrage rapide (2 pages), Manuel de démarrage rapide (2 pages)

4RF Aprisa SR+ Manuel

8 | Demonstration Procedure

4.
Demonstration Procedure
All commands to be typed are shown in italics.

Basic Operation

1. Open Internet Explorer and access 172.17.200.10
a. Username:
b. Password:
2. Show basic Web browser management
a. Tab through the various screens and explain about remote management
3. Show Test Button operation
a. Press and hold the Test Button on remote radio 1 until the LEDs flash. Five green LEDs
should appear indicating >-80 dBm RSSI
b. Disconnect the RF cable on remote radio 1 and hold it close to the RF connector. The
LEDs should turn orange
c. Pull the cable away completely and the LEDs should turn red
d. Reconnect the cable. The LEDs should turn back to all green
e. Press and hold the Test Button until the LEDs flash to exit the test mode
4. Open Terminal Emulator configured for RS-232 serial data and show transfer of a text file
a. Fit the RJ45 RS-232 loopback plug to remote radio 1 serial port 1
b. Send a text file from the base station. The details should reappear on the screen
indicating that the file has been sent to that remote station, looped back at the remote
station RS-232 serial port and sent back to the base station
c. Remove the RS-232 loopback connector from the remote radio 1 and re-demonstrate
showing the break in the loopback connection
5. Open cmd window and show Ethernet data transfer – note the flashing of Tx and Rx LEDs
a. ping 172.17.200.20
b. ping 172.17.200.30
6. Show data compression
a. In cmd window: ping 172.17.200.30 –l 1000
b. Ping test should show transfer of 1000 bytes to be almost as fast as the 32 byte transfer
from previous test
7. Show Ethernet and RS-232 serial. This test pings Remote Station 2 and loops back serial data
through remote radio 1
a. Fit the RJ45 RS-232 loopback plug to remote radio 2 serial port 1
b. In cmd window: ping 172.17.200.20 –t
c. With the Terminal Emulator, send serial data
d. In cmd window Ctrl C to stop the Ethernet test
admin
admin
Aprisa SR+ Demo Kit Guide 1.3.0