HIBLOW HP Series Manuel - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} HIBLOW HP Series. HIBLOW HP Series 9 pages.
Également pour HIBLOW HP Series : Manuel (5 pages), Manuel (8 pages), Manuel de démarrage rapide (7 pages)
HP- 100 / 120
STEP
STEP
FITTING THE CHAMBER BLOCKS
12
12
Fit the actuating rod by aligning it with the groove
and tighten U-lock nut and flat washer by the nut
driver.
●Use new U-lock nut and washer, otherwise, U-lock nut
may work loose and cause malfunction.
STEP
STEP
13
13
Insert the actuating rod into the machine body. Be
sure to fit the positioning boss on the diaphragm
base into the concave part of the frame stay.
Secure the diaphragm mounting block on the
other side and tighten washers and U-lock nuts
with the nut driver.
Make sure that gap between the actuating rod
and the electromagnets is even.
STEP
STEP
14
14
Mount the casing block with screws (4 screws on
each side).
And insert L-tube into the nozzle of casing A.
Then, fix it with hose clip.
Complete the other casing block in the same way.
STEP
STEP
REPLACEMENT OF SAFETY PIN
15
15
Check that the broken pin is removed from unit.
●If the broken pin is left inside the unit, it can get caught
in between electromagnets and actuating rod, which
can cause breakdown.
REPLACING THE CHAMBER BLOCK
5