Dynamite DYN4064 Manuel d'utilisation - Page 13

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Dynamite DYN4064. Dynamite DYN4064 20 pages. Passport ultra ac/dc charger cycler

Dynamite DYN4064 Manuel d'utilisation
li-ion/Poly Balance Charge
warning Message
WARN
Volt Select Err
1. Set Wrong Battery Voltage
Balancer
No Connect
2. Balance Leads not Connected
Unbalance Volt
Over
3. Shows that the unbalanced voltage is above
the 10mV limit at 30mV. The charge will
automatically switch to a 100mA charge rate
until the battery cell voltages are balanced to
less than 10mV. The charger will begin normal
charging after the cells are balanced.
Cell Number 1
Volt Over 4.26V
4. Battery voltage is over 4.26V per cell.
See previous step. The charger will drop to a
low current rate until the cells are balanced
within specifications.
Dynamite Ultra AC/DC Charger/Cycler
See the status by turning the dial during
discharge.
30mV
1. Selected Discharge Voltage Cutoff
Discharge voltage is pre-set to 3.00V/cell and
the corresponding S count will be displayed
along side the voltage cutoff being selected.
Selecting the correct S count will automatically
set the appropriate voltage cutoff.
2. DC Input Voltage/System Temperature

li-ion/Poly Discharge Mode

Li-Poly Dischg
1.0A 12.0V(4S)
Message during li-ion/Poly Discharging
Li4S 0000:01 0001
DIS 1.00A 15.18V
Select Voltage
12.0V (4S)
Input
System Temp 36°C
13.01V
www.DynamiteRC.com
13