909 KSBL26CCG Manuel d'instruction - Page 14
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} 909 KSBL26CCG. 909 KSBL26CCG 15 pages. 26cc full crank key start petrol blower
Problems
Power loss or sudden stopping of the engine
•
Check whether the fuel tank is empty.
•
If there is water in the mixture. Drain and rinse the fuel
system with petrol.
•
If the air filter is dirty. Clean the air filter.
Starting a flooded engine
•
D isconnect the spark plug lead, and use the plug wrench
to remove the spark plug in a counter clockwise direction.
•
If the spark plug is fouled or is soaked with fuel, clean or
replace the plug as required.
•
Clean excess fuel from the combustion chamber by
cranking the engine several times while the spark plug
is removed. Ensure On/Off switch is Off.
•
Install the spark plug and firmly tighten it with the spark
plug wrench.
•
Repeat the starting procedure as if the blower was
already warm.
Adjusting the engine idle speed
•
If your blower is delivering poor performance or
running roughly then you may need to adjust the
engine idle speed.
•
Start the blower engine.
•
Run the engine at idle speed
until operating temperature is
reached: approximately 2–3
minutes.
•
Use a screwdriver to adjust
the engine idle speed.
•
Turn the idle screw clockwise
to increase engine idle speed.
•
T urn the idle screw counter-clockwise to decrease engine
idle speed.
IMPORTANT.
Blower tubes and intake cover must be
installed while adjusting engine idle speed. Engine idle
speed will also be affected if either the intake cover or
blower tubes are blocked, damaged or incorrectly installed.
14