Autonics CT Series Manuel - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Autonics CT Series. Autonics CT Series 13 pages. Programmable digital counters / timers
Également pour Autonics CT Series : Manuel (4 pages), Manuel du produit (11 pages)

Autonics CT Series Manuel

2. Technical Specification

Power Supply
Allowable Voltage Range
INA INB input frequency
Counter
Min.input
Signal width
Timer
Input
One-shot output
Contact Point
Capacity
Control
Solid State Relay
Output
Capacity
Memory time
External sensor power
Timing Accuracy
Insulation resistance
Dielectric Strength
Anti-interfere
Mechnical
Vibration
Malfunction
Mechnical
Shock
Malfunction
Mechnical
Relay
life cycle
Electrical
Work temperature
Storage temperature
Storage humidity

3.Panel Indication

PS1: Indicate that setting value of OUT1
being displayed on the below LED
PS2: Indicate that setting value of OUT2
being displayed on the below LED
BA.S:Above LED display batch counting value
Below LED display batch setting value
Reset
Batch setting key
90~110% of rated voltage(AC power)
1Hz, 30Hz, 1KHz , 5KHz ,10KHz are selectable
Reset input: Selectable 1ms or 20ms
INA, INHIBIT, RESET, BATCH RESET: Selectable 1ms or 20ms
Selectable voltage input or Non-voltage input
Voltage input : Input impedance:5.4k , H level :5 -30VDC, L level: 0-2VDC, L level: Max.2VDC,
Non -voltage input :Short-circuit impedance:Max.1k,Residual voltage:Max.2VDC,
OPen-circuit impedance:Min.100k
10/50/100/200/500/1000/2000/5000ms
NO:250VAC 3A at resistive load, NC:250VAC 2A at resistive load
Max. 30VDC , Max. 100mA
memory datasheet for 10 years
12V DC
Power on start accuracy:
Signal start accuracy :
Min 100M
2000V AC 50/60Hz 1minute
2kV , the square wave generator interference ( pulse width: 1uS)
amplitude : 0.75mm , frequency : 10 55Hz, X , Y , Z directions each for 1 hour
amplitude: 0.5mm , frequency:10 55Hz , X , Y , Z directions each for 10 minutes
300/S
( about: 30G) X , Y , Z directions for 3 times each
2
100/S
( about: 10G) X , Y , Z directions for 3 times each
2
more than 10,000,000 times
More than 100,000 times , (NO: 250VAC 3A load , NC: 250V AC 2A load)
PS1
PS2
BA.S
LOCK
OUT1
OUT2
BA.0
RST
BA
MD
Function key Parameter modifying key
Page 02
100-240V AC/DC
10%, Maximum 100mA
0.05%
0.05%
0.03sec
( at 500V DC)
~
~
-10 ~ +50
℃(at non-freezing status)
+65
℃ (at non-freezing status)
35
85%RH
~
Lock:
Key lock indication
OUT1,OUT2: OUT1 or OUT2 output indicate
BA.0 :Batch output indicate(CT3,CT4 without indicate light)
CNT: Counting mode
CNT
TMR
TMR:Timing mode
0.05sec
(CT16,CT8 without indicate light)
KKCTE02T-A/0-20131221