6
a
b
ø 6
mm
d
e
PN80456
a: Remove the strut from the panel, place an inner wall bracket in the marked
position and mark the fixing hole onto the wall.
b: Drill the position marked using a 6mm drill bit, 30mm deep.
c: Insert the wall plug and fix the inner wall bracket to the wall using a 38mm
screw and washer.
Note: The screws and wall plugs supplied are for masonry walls. For
lightweight walls i.e. stud partitions, plasterboard etc, use the correct type
9
Vertical strut installation
Opening
Wall
=
=
Ensure that the opening end of the panel is vertical and
the panel is parallel with the opposite wall.
c
g
38
mm
f
d: Slide wall bracket cover onto the strut.
e: Reposition the strut into the inner wall bracket and the other end (with panel
bracket fitted) onto the glass panel (with grub screws on the inside). Screw the
wall bracket cover onto the inner wall bracket.
f: Tighten the wall bracket cover grub screw.
g: From inside, slide the glass clamp up between the bracket and glass panel,
tighten the grub screw (1). Ensure the panel is vertical and tighten the grub screw
10
a
b
a: Unscrew the top section of panel bracket.
b: Remove the long grub screw fixing the two halves together.
c: Fix the wall bracket to the lower section of panel bracket using the 16mm screw.
7
2
1
Inside
Push-fit the top cap onto the top of
the wall channel.
a
11
c
16mm
Wall
a: Carefully place the (reassembled) panel bracket onto the glass, approximately 100mm from the edge (depending
on your installation). Carefully measure the distance 'X' between the top of the panel bracket and the ceiling.
b: Trim the strut to length: X + 30mm.
8
Outside
From outside only, From outside only, apply silicone
sealant along the bottom of the panel as shown.
b
Ceiling
X
X + 30mm
100
mm