AFL FlexScan FS300 Manuel de référence rapide - Page 17

Parcourez en ligne ou téléchargez le pdf Manuel de référence rapide pour {nom_de_la_catégorie} AFL FlexScan FS300. AFL FlexScan FS300 20 pages. With smartauto and linkmap

AFL FlexScan FS300 Manuel de référence rapide
Fiber test results
may be stored in the FlexScan internal memory or external USB stick.
A
Saved test results are organized into a Fiber Group sub-folder
Results - Fibers
Save As Screen
F
G
Touch Results
to display File Manager and navigate to the desired Project / Fiber Group folder.
F
Project, End 1, End 2, and Cable are user-defined in Text Editor.
Fiber number auto-increments after each save, but can be modified in Number Editor as needed.
Touch Done
when finished.
G
For Bi-directional OTDR reports, results must be obtained and stored from each end of the network:
Use same test settings (range, pulse width, etc.) in both directions; Use same launch and receive cables in both
directions; Swap End1, End2 names; Bi-directional averaging and report generation is performed using TRM 3.0.

File Manager

Fiber Groups
A
A name of the saved result consists of several parameters, which are
D
defined in the Save As screen
End 1_End 2_Cable_Fiber#_Wavelength
Fiber Group Name
within a Project folder
B
B
E
.
D
E
Fiber#
17
.
C
Projects
S13 for 1310 nm
S15 for 1550 nm
M85 for 850 nm
M13 for 1300 nm
C