Siemens sitrans Manuel d'instruction - Page 12
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Siemens sitrans. Siemens sitrans 20 pages. Variable frequency drives and instrumentation using variable frequency drives and instrumentation without interference
Également pour Siemens sitrans : Manuel (8 pages)
Accessory Mounting
Extension Tab
Screw Sensor into threaded hole of tab,
and fasten onto device being monitored.
Notes:
•
If welding, weld must be a continuous bead. Tacking does not provide
sufficient acoustical coupling.
•
Do not arc weld on equipent connected to a SITRANS AS 100. Remove the
SITRANS AS 100 or disconnect electrically to avoid current flowing through
the sensor.
•
If gluing, use Loctite 326 adhesive, or equivalent. Follow manufacturer's
instructions to ensure proper adhesion.
Temperature Considerations
Warning: Temperature at Sensor must not exceed minimum or
maximum ratings.
Ensure adequate isolation from hot
surfaces by providing additional
spacing.
for standard Temperature
Note:
range model, maximum
temperature is 80 °C.
*maximum range dependent on model.
Page 8
< 80 ºC
>80 ºC
SITRANS AS 100 – INSTRUCTION MANUAL
Mounting Disc
Screw Sensor into disc, after welding or
bonding disc onto device being monitored.
Tab acts as heat sink.
Note: If the flange temperature is 100 °C
and the ambient temperature is 20 °C,
the Sensor temperature at the
electronics is below the maximum
rating.
20 ºC
100 ºC
65 ºC
7ML19985DM02