Siemens sitrans 사용 설명서 - 페이지 12

{카테고리_이름} Siemens sitrans에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens sitrans 20 페이지. Variable frequency drives and instrumentation using variable frequency drives and instrumentation without interference
Siemens sitrans에 대해서도 마찬가지입니다: 매뉴얼 (8 페이지)

Siemens sitrans 사용 설명서
Accessory Mounting
Extension Tab
Screw Sensor into threaded hole of tab,
and fasten onto device being monitored.
Notes:
If welding, weld must be a continuous bead. Tacking does not provide
sufficient acoustical coupling.
Do not arc weld on equipent connected to a SITRANS AS 100. Remove the
SITRANS AS 100 or disconnect electrically to avoid current flowing through
the sensor.
If gluing, use Loctite 326 adhesive, or equivalent. Follow manufacturer's
instructions to ensure proper adhesion.

Temperature Considerations

Warning: Temperature at Sensor must not exceed minimum or
maximum ratings.
Ensure adequate isolation from hot
surfaces by providing additional
spacing.
for standard Temperature
Note:
range model, maximum
temperature is 80 °C.
*maximum range dependent on model.
Page 8
< 80 ºC
>80 ºC
SITRANS AS 100 – INSTRUCTION MANUAL
Mounting Disc
Screw Sensor into disc, after welding or
bonding disc onto device being monitored.
Tab acts as heat sink.
Note: If the flange temperature is 100 °C
and the ambient temperature is 20 °C,
the Sensor temperature at the
electronics is below the maximum
rating.
20 ºC
100 ºC
65 ºC
7ML19985DM02