Note
The 1250 series power injector, 1250 series DC power module, and
antennas are not tested to UL 2043 and should not be placed in a
building's environmental air space.
Connecting Power
The access point can be powered locally by the 1250 DC power module or an
IEEE 802.3af compliant Power-over-Ethernet (PoE) power source. However,
if the access point is powered by an 802.3af source, only one radio is
supported because the two radio operation requires 18.5 watts. Two radio
operation is supported only by the 1250 series power injector and an 802.at
compliant PoE switch.
IEC60950 and IEEE 802.3af devices include:
•
A 1250 DC power module connected to the access point's power
connector
– The 1250 DC power module should be plugged into a 100-240 VAC
source
•
The following devices provide PoE:
– An IEEE 802.af compliant power source
16