Leveling screws
Adjust the leveling set screws as follows:
 Insert, but do not tighten 8-32 (M4) reading head screws
as shown on the right side.
 Place a 0.025 mm - 0.075 mm (0.001"- 0.003") shim between
the leveling set screws and mounting surface.
 Adjust each set screw until a slight drag is felt on the shim.
 Remove the shim before tighten the reading head screws.

Mounting the reading head

M3 x 12 mm SHSS
M4 x 25 mm SHCS low head
(8-32 x 5/8" SHCS low head)
(8-32 x 3/4" SHCS low head)
Mounting the reading head with hex nut
M4 hex nut
Do not tighten prior to adjusting leveling set screws.
Evenly tighten the 8-32 (M4) reading head mounting screws.
Removing the alignment brackets
Slide brackets away from reading head and cable.
 Slide the brackets away from the reading head.
 Remove the alignment brackets and save for future use.
7 Mounting the reading head
M4 x 25 mm SHCS low head
(8-32 x 5/8" SHCS low head)
(8-32 x 3/4" SHCS low head)