Aeon Labs Nano Shutter Manuel de l'utilisateur - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Aeon Labs Nano Shutter. Aeon Labs Nano Shutter 10 pages.
The Nano Shutter can be controlled via 2-state (flip/flop) external/manual switch, momentary push button or the 3-way
switch. To automatically detect and set the mode to the appropriate type of manual switch wired into Nano Shutter, toggle
the button on the manual switch once and wait 2 seconds for the Nano Shutter to detect the type of manual switch.
You can also set the external switch mode through Configuration Command Class.
Parameter 120 [1 byte] (for S1) and Parameter 121 [1 byte] (for S2) is the parameter that will set one of the 3 different
modes. You can set this configuration to:
(0) Unknown Mode
(1) 2-state switch mode
(2) 3-way switch mode
(3) Momentary push button Mode
(4) Enter auto switch detection mode
Compatible external switches and their use case.
Our Nano Shutter currently only supports 3 different external Wall Switches:
1. Standard Toggle Switch (2-way / 3-way / 4-way)
- Toggle UP (high voltage) - toggles On.
- Toggle DOWN (low voltage) - toggles Off.
2. Momentary Push Button
- Tap once - toggle On / Off.
- Press and Hold for 20 seconds or more - factory reset Nano Shutter.
3. WallSwipe for Nano
- Tap area - depending on the area you tap, you can toggle ON/OFF.
- Swipe up gesture - turn on lights.
- Swipe down gesture - turn off lights.