12. MOTOR REPLACEMENT Cont.
• Next remove the rear Fan Blade by first removing the nine Phillips screws attaching the Heater Housing to the Rear Panel
(Fig. 12-6). Then remove the Fan Blade Clamp and slide the Rear Fan Blade from the Motor Shaft (Fig.12-7). Now remove the
four 8mm Motor Mounting Bolts and the Motor can be removed and replaced.
12. MOTOR INSTALLATION
TECH NOTE: With the Drum Belt loose, dry fit the new Motor and align the four Motor Mounting Bolt Screw Holes of the Motor with
the four rear bolt hole openings on the Base. Then mark both the Motor and the Motor Base with a reference line (Fig. 12-9). This will
make it easier to install the Motor and align the bolt holes and threads as you hold tension on the belt while inserting the four bolts.
• With your reference line in place, install the Belt around the Motor Shaft and Pulley. Now using a screwdriver tension the belt.
When your two reference lines are aligned insert one of the 8mm Motor Mounting Bolts and secure (Fig.12-10). Then install the
other three Mounting Bolts and reinstall all Motor Components and test.
REPAIR MANUAL
Fig. 12-6
TECH NOTE
Fig. 12-9
Fig. 12-7
ASL75CXS NA
Fig. 12-8
Fig. 12-10
Page: 11