20. Insert the GROOVE PIN into the hole in the LEVER until it has
gone past the gap in the LEVER and into the hole on the opposite
side of the LEVER. Do not hammer the pin into place at this time.
21. Slide the LOCK WASHER over the LEVER SCREW and apply
"Never Seize" to the LEVER SCREW.
22. Install the SCREW into the LEVER and tighten firmly to squeeze
the LEVER against the hex of the CAM SHAFT.
23. Hammer the GROOVE PIN into the LEVER until flush.
24. Turn the coupler so that you can look into the open end nearest
the LEVER.
25. Insert the COTTER PIN into the hole in the main SHAFT and
using the LEVER to rotate the CAM SHAFT as needed, completely
flair the COTTER PIN.
26. Adjust the POPPET by rotating the LEVER to the open position
and rotating the POPPET left or right to increase or decrease the
compression on the SEAL CYLINDER. The POPPET is properly
adjusted when the seal on the SEAL CYLINDER is just barely
separated from the face of the BLANK ADAPTER (about 1/32") when
the coupler LEVER is rotated to the closed position. There will be a
noticeable 'over center' feel to the lever as it enters its closed
position. The LEVER should tend to stay closed when rotated to its
closed position. If it does not, open the LEVER and readjust the
POPPET by threading it down further into the BODY then repeat this
step.
27. With the POPPET correctly adjusted, tighten the SET SCREW in
the POPPET securely against the YOKE. This requires 55 FT-LB of
torque. This is necessary to prevent the POPPET from rotating out of
adjustment.
28. Install the O-RING under the head of the POPPET SCREW.
Apply "Never Seize" to the SCREW and tighten into the POPPET.
29. With the coupler in the closed position, unlock and open the CAM
ARMS and remove the BLANK ADAPTER.
30. Install the main GASKET.