6 System Troubleshooting and Maintenance
For troubleshooting issues related to 3500E, see the 3500E Operator's Manual
Check in order as listed
System is not powering on
• Check if system is plugged in.
• Check if power cord wires are loose or unsecured in the terminals.
• Check if power outlet or lead is functioning correctly.
System is not activating solenoids or spray gun
• Check connections from PLC and to the terminals. See wiring diagrams for
correct connections if necessary.
• Check connections to solenoid caps or EPG SPRINT connector.
• If the lights inside the solenoid caps are functioning, check the
connection between the cap and solenoid on the 3500E.
LCD screen not displaying correct window
This error can occur from pressing the OK and ESC buttons at the same time
• Press any button on the PLC inside the ETC.
• Turn the ETC off and on.
Recommended Spares
3500-ETC Operator's Manual
Description
Lighted cap for solenoid 24VDC
Cable gland
Part Number
E-01013-61
110VAC
E-01013-11
69915K54
Quantity
1
1
P a g e | 9