5 Operation

System Spray Cycle
When the PLC or machine output is on (A), the ETC will
perform a cycle of the 3500E automatically. The Fluidizing Air
Valve will open at the start of the cycle and remain on for
the set time (B), and the spray gun will fire for the set time
(C)
while the Fluidizing Air Valve is on. The dust collector will
turn on at the start of the spray cycle and continue for a
(D)
set time
While running automatically, the system should cycle as described above, and
the spray volume and pattern should be consistent. See the 3500E Operator's
Manual for troubleshooting spray output issues.
Modifying System Cycle Settings
• Observe the current settings on the LCD screen located
inside the ETC enclosure.
• Press the right button on the PLC to move between
individual settings screens.
• Once screen with the setting that needs to be changed
is reached, press the up button to increase the time and
the down button to decrease the time.
• Minimum timings are as follows:
o Fluidizing Air – 0.5s (0.1s increments)
o Spray On – 0.5s (0.1s increments)
o Collector – 1.0s (1s increments)
3500-ETC Operator's Manual
after spraying.