AMCOL 3500-ETC Panduan Operator - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Operator untuk Pengontrol AMCOL 3500-ETC. AMCOL 3500-ETC 12 halaman. Electronic timing controller
Juga untuk AMCOL 3500-ETC: Deskripsi Teknis (8 halaman)

4 Recommended Settings

Power In
Item ID
Description
A
Control Input
B
Fluidizing Air
Valve
C
Spray Time
D
Collector
3500-ETC Operator's Manual
Fluidizing Air Valve
Recommended Setting
Energize to initiate spray cycle, de-energize before
the spray cycle ends
Set to at least 1 second
Set according to billet size (start at 0.5s, increase
for larger billets)
Set to at least 1 second
EPG SPRINT
Controller
VS-550 Dust
Collector
A
B
C
D
P a g e | 6