Acer AL1913c Panduan Servis - Halaman 11
Jelajahi secara online atau unduh pdf Panduan Servis untuk Monitor Acer AL1913c. Acer AL1913c 42 halaman.
Juga untuk Acer AL1913c: Panduan Servis (42 halaman)
Luminance of center point: L=L(5)
Brightness Uniformity Measurement points: Five specified points 1-5
Formula: Maximum [L (1), L (2), L (3), L (4), L (5)]/Minimum [L (1), L (2), L (3), L (4),
L (5)]
(3)
Definition of Response Time (T
100%
90%
Optical
10%
Response
0%
(4)
Measurement Setup:
The LCD module should be stabilized at given temperature for 20 minutes
to avoid abrupt temperature change during measuring. In order to stabilize
the luminance, the measurement should be executed after lighting Backlight
for 20 minutes in a windless room.
LCD Module
LCD Panel
Center of the Screen
, T
R
Gray Level 255
T
R
Field of View = 2 º
500 mm
11
):
F
Gray Level 255
Gray Level 0
Photometer
(TOPCON BM-5A)
Light Shield Room
(Ambient Luminance < 2 lux)
T
F
Time