Acer AL1913c Servicehandleiding - Pagina 11

Blader online of download pdf Servicehandleiding voor {categorie_naam} Acer AL1913c. Acer AL1913c 42 pagina's.
Ook voor Acer AL1913c: Servicehandleiding (42 pagina's)

Acer AL1913c Servicehandleiding
Luminance of center point: L=L(5)
Brightness Uniformity Measurement points: Five specified points 1-5
Formula: Maximum [L (1), L (2), L (3), L (4), L (5)]/Minimum [L (1), L (2), L (3), L (4),
L (5)]
(3)
Definition of Response Time (T
100%
90%
Optical
10%
Response
0%
(4)
Measurement Setup:
The LCD module should be stabilized at given temperature for 20 minutes
to avoid abrupt temperature change during measuring. In order to stabilize
the luminance, the measurement should be executed after lighting Backlight
for 20 minutes in a windless room.

LCD Module

LCD Panel

Center of the Screen
, T
R
Gray Level 255
T
R
Field of View = 2 º
500 mm
11
):
F
Gray Level 255
Gray Level 0
Photometer
(TOPCON BM-5A)
Light Shield Room
(Ambient Luminance < 2 lux)
T
F
Time