Acer AL1913c Servis Kılavuzu - Sayfa 11

Monitör Acer AL1913c için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Acer AL1913c 42 sayfaları.
Ayrıca Acer AL1913c için: Servis Kılavuzu (42 sayfalar)

Acer AL1913c Servis Kılavuzu
Luminance of center point: L=L(5)
Brightness Uniformity Measurement points: Five specified points 1-5
Formula: Maximum [L (1), L (2), L (3), L (4), L (5)]/Minimum [L (1), L (2), L (3), L (4),
L (5)]
(3)
Definition of Response Time (T
100%
90%
Optical
10%
Response
0%
(4)
Measurement Setup:
The LCD module should be stabilized at given temperature for 20 minutes
to avoid abrupt temperature change during measuring. In order to stabilize
the luminance, the measurement should be executed after lighting Backlight
for 20 minutes in a windless room.

LCD Module

LCD Panel

Center of the Screen
, T
R
Gray Level 255
T
R
Field of View = 2 º
500 mm
11
):
F
Gray Level 255
Gray Level 0
Photometer
(TOPCON BM-5A)
Light Shield Room
(Ambient Luminance < 2 lux)
T
F
Time