3. (SEE FIGURE 3) Connect parts (D) medium
basin, (E) top pedestal and (F) small basin
together. Thread the PVC tube from finial
top (G) through the fountain assembly of
parts (D, E & F).
4. Taking the fountain assembly, thread the PVC
tube into the center pedestal (C) align the tabs
and notches of the fountain assembly and
secure by twisting.
5. With help, carefully lift the fountain assembly
slightly, find the PVC tube, and connect the
PVC tube to the top of the electric pump spout.
Align the tabs and notches and secure the
complete fountain assembly by twisting.
6. Plug the light connectors from the light ring (I)
to the connectors from the electric pump (H),
and then push them into the center pedestal
and under the light ring to hide and secure the
door (retained from step 2) back on the base
of the center pedestal (C).
7. (SEE FIGURE 4) Fill the large basin (A) with
water; if possible use distilled water to fill
the fountain.
8. Plug the power cord from the transformer (J)
into properly grounded 120V AC outlet.
Adjust Speed of Water Flow
1. Unplug pump (H) from AC power outlet.
2. Move adjustment switch on pump (H)
toward "+" positive to increase water
flow, or "-" to decrease water flow.
Maintenance
1. Check water level periodically, add
water if necessary.
2. If water is not flowing, check electric pump (H),
and the clear tubing (K) for clogs.
NOTE: Pump may build up calcium after a
long period of time and stop running when
tap water is used. Any calcium remover can
be used to clean pump.
Figure 3
G
F
Pedestal
Notch
E
D
Basin Tab
C
Figure 4
Grounded
Outlets
A
4
ELECTRICAL SAFETY INSTRUCTIONS
WARNING!
ELECTRICAL SHOCK. Read and understand all instructions. Failure to follow all
instructions listed below, may result in electrical shock, fire and/or serious personal injury.
Grounding Instructions
This fountain must be plugged into a 3-wire, 3-prong outlet that is properly working and has
been installed and grounded in accordance with all local, state or federal codes and ordinances.
DANGER:
IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK OF
ELECTRICAL SHOCK. Check with a qualified electrician or serviceman if the grounding instructions
are not completely understood, or if doubt as to weather the product is properly grounded. Do not
modify the plug provided; if it will not fit the outlet, have a proper outlet installed by a qualified
electrician. Do not use any type of adapter with this product.
Outdoor Use Extension Cords
1. When product is used outdoors, use only extension cords marked for outdoor use.
2. Use only UL listed extension cords. Never use damaged or altered extension cords.
3. Follow extension cord manufacturer safety instruction.
Extension Cords
H
1. Make sure your extension cord is in good condition.
2. When using extension cords, be sure to use one heavy enough to carry the current your product
requires. An undersized cord will cause a drop in line voltage resulting in power loss and
overheating. Reference Table 1 at the bottom of the page for the correct size to use depending
on cord length and nameplate Ampere rating. If in doubt, use the next heavier gage. The smaller
the gage number, the heavier the cord.
Table 1. Minimum Recommended Extension Cord Gauge (AWG) Chart
J
SAVE THESE INSTRUCTIONS.
AMP Load
Volts Extension Cord Length
120V
25'
50'
100'
AWG
1-5
18
16
16
6-10
18
16
14
10-12
14
14
14
12-16
14
12
Not recommended
1
150'
14
12
12