Cansec MAP2 Panduan Instalasi - Halaman 13

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Pengontrol Cansec MAP2. Cansec MAP2 16 halaman. Elevator control

Cansec MAP2 Panduan Instalasi

MAP2 PLM COMMUNICATION

MAP2 to H1000 Panel Communication LEDs

If the MAP2 elevator control panel has been correctly configured as a 32 to 64 floor
elevator system, the two LEDs on the Panel Logic Module (PLM) daughter board will
indicate the RS485 communication to the auxiliary H1000 panels. The PLM LEDs are
labeled TX485 (Green LED1) and RX485 (Red LED2). If no auxiliary H1000 panels are
connected to the MAP2 elevator control panel, the TX485 (Green LED1) will toggle On
and Off. If all the auxiliary H1000 panels are configured and connected correctly, both
TX485 (Green LED1) and RX485 (RED LED2) will toggle On and Off.
TX485 LED
RX485 LED
MAP2 Elevator Control
Page 13 of 16
Installation Guide
April 2020 • Rev. 1.0