Baumer DENEX Gripper LED Panduan Pengguna - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Aksesori Baumer DENEX Gripper LED. Baumer DENEX Gripper LED 24 halaman.

Baumer DENEX Gripper LED Panduan Pengguna
7

LED INDICATORS

There are four LED's that are placed close to the connector for checking the operation of
the sensor,
POWER (GREEN)
LED OFF (RED)
OUTPUT (ORANGE)
STATUS (YELLOW)
7.1

The POWER-LED

The green POWER-LED indicates that the sensor has power and should be operating.
Never mount or adjust the sensor when this LED is on!
7.2

The "LED OFF"- LED

The "LED OFF"-LED is an indication that the light emitting diode is off. The LED could be
shut off for the following reasons:
• The LED-power level has changed in an uncontrolled way (electronic problem inside
sensor)
• The LED-power level is too low to ensure a good operation
If the LED-levels are outside of the allowed limits, the sensor must be sent for repair.
7.3

The OUTPUT- LED

The OUTPUT-LED is active when the output stage is active (set). The LED will flash for
every output pulse that is sent. The output pulse width can be set with the DIP-switches,
see chapter 6.4, "DIP-Switch Settings". By watching this LED, it is fairly easy to see that
the sensor is giving the correct amount of pulses.
7.4

The STATUS- LED

see chapter 6, "SOFTWARE FUNCTIONS".
User Manual DENEX Gripper LED
Version 2013-02, V1.4
Figure 7.1 Position of LED:s.
14/24
www.baumer.com
Baumer Electric AG
Frauenfeld, Switzerland