COMBA CriticalPoint BBU V2 Panduan Instalasi Cepat - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Instalasi Cepat untuk Sistem Konferensi COMBA CriticalPoint BBU V2. COMBA CriticalPoint BBU V2 10 halaman. Annunciator panel
Juga untuk COMBA CriticalPoint BBU V2: Panduan Instalasi Cepat (11 halaman)

COMBA CriticalPoint BBU V2 Panduan Instalasi Cepat

Troubleshooting

If annunciator does not power on or does not appear in BBU GUI after wiring has been confirmed, use a multimeter to
check the following pins for resistance and voltage according to the below instructions.

BBU Measurements

1. Turn on the BBU.
2. Measure voltage from 1->3 and 2->3.
1 to 3
2 to 3
1. Turn off the BBU.
2.
Measure the resistance from 1->3, 2->3, and 1->2.
1 to 3
2 to 3
1 to 2

Annunciator Panel Measurements

1. Turn ON the annunciator panel.
2. Measure voltages across 1->3 and 2->3
Voltage should be around 1.65V +- 0.05V.
1 to 3
2 to 3
©2021 Comba Telecom. All Rights Reserved.
568 Gibraltar Drive, Milpitas, CA 95035 | +1 866 802 7961 |
BBU V1
www.combausa.com
~ 1.65 VDC
~ 1.65 VDC
~ 450 Ohms
~ 450 Ohms
~ 50 Ohms
~ 1.65 VDC
~ 1.65 VDC
BBU V2
Version 1.0.0
9