Table 1.
Dispensing Valve Plumbing Configurations
Valve Diagram
AIR IN
AIR IN
MATERIAL IN
U S E R G U I D E
D V C - 3 4 5 V A L V E C O N T R O L L E R
|
Plumbing Instructions
Model 300: Single-acting, normally closed diaphragm
valve.
Plug Port No. 1 (normally open) on the back of the
controller and plumb Port No. 2 (normally closed) to
the Air-In Port on the dispensing valve.
Model 455: Single-acting, normally closed pinch
valve.
Plug Port No. 1 (normally open) on the back of the
controller and plumb Port No. 2 (normally closed) to
the Air-In Port on the dispensing valve.
Model 475: Single-acting, normally closed diaphragm
valve.
Plug Port No. 1 (normally open) on the back of the
controller and plumb Port No. 2 (normally closed) to
the Air-In Port on the dispensing valve.
Model 775: Single-acting, normally closed spool
valve.
Plug Port No. 1 (normally open) on the back of the
controller and plumb Port No. 2 to the Air-In Port on
the dispensing valve.
Model 826: Single-acting, normally closed pinch
valve.
Plug Port No. 1 (normally open) on the back of the
controller and plumb Port No. 2 to the Air-In Port on
the dispensing valve.
9