8 . Install compression nuts and sleeves to each tube end .
9 . Shift tube ends to install WaterCop
10 . Position the unit and tighten compression nuts . Hold the fitting with one wrench while tightening the nut with the other .
Tighten both nuts .
11 . Plug unit into a proper power source and turn valve to open position (open button / green light) .
12 . Unplug unit, turn water back on and carefully check for leaks .
13 . Tighten fittings if needed to stop any leaks .
14 . Plug unit back into power source . Installation is complete .
Solder Fittings
An alternative method is to solder the unit into the water line . This method requires a considerably higher skill level to
accomplish the installation properly and safely . If you are not skilled in this area, it is strongly recommended that you
contact a professional plumber to do this type of installation .
Electrical Connection
The WaterCop
is supplied with a power adaptor (20' cord) to be plugged into a 120 VAC power source . It is recommended
®
that the WaterCop
not be plugged into an extension cord .
®
Review "Specification" current and power requirements as not to overload the circuit supplying power .
As with all valuable electronic items; we recommend plugging the WaterCop
Warnings and Precautions
WARNING!
STOP
The motorized drive unit case is not capable of supporting any loads. Do not attempt to use the
unit as a step. This will cause damage to the unit and could cause personal injury. Do not store
highly flammable items such as oily rags or other combustibles near your WaterCop
Caution:
It is recommended that eye protection be worn while installing or servicing the system. Failure to do
so could result in personal injury.
Caution:
Do not use the case as leverage when mounting this unit or tightening fittings. Apply wrench to flats
on the valve body to tighten fittings.
Changing Digital Codes
Codes on all control units and transmitters are set at the factory and should not require alteration . If you use other wireless
products in your home (garage door openers, etc . ) , there is a slight chance of interference with the signal . The following
instructions will aid in resetting the code .
Important Note: All transmitters and the control unit must have the same code setting!
Changing the Receiver Code
Disconnect power to receiver unit by unplugging power cord .
1 . Remove cover using the 4 screws located in the corners of the cover .
2 . Locate code switch block (see illustration page 12) . Switches are numbered 1 through 8 .
3 . Arrange the switches in any combination (on or off position) . Write down the code combination you selected .
Example: 1-on, 2-off, 3-off, 4-on, 5-off, 6-on, 7-off, and 8-off .