OPERATING INSTRUCTION
Power
Make sure the Power Switch, located on the control panel, is in the OFF position. Plug the power
cord into a 110~120 Volt 15 Amp outlet. Make sure the outlet is in good condition and that the plug
is not loose. NEVER exceed the maximum amperage for the circuit. DO NOT plug other appliances
into the same circuit.

Temperature Limiting Control

This heater is equipped with a Temperature Limiting Control. Should the heater reach an unsafe
temperature, the heater will automatically turn OFF. To reset:
1.
Unplug the power cord from the outlet.
2.
Turn the Power Switch on the CONTROL PANEL to OFF. Wait at least 5 minutes.
3. Inspect the fireplace to make sure no vents are blocked or clogged with dust or lint. If they
are, use a vacuum to clean the vent areas.
4.
With the Power Switch in the OFF position, plug the power cord back into the outlet.
5. If it switches off again, UNPLUG THE HEATER RIGHT AWAY! Have the outlets, wiring,
and breaker box inspected by a professional. Make necessary repairs before using the
heater .
Heater Rating
Maximum heat output: 1500W (4600BTU); Maximum heating area: 400 square feet.

Operation

Read and understand this entire owner's manual, including all safety information,
before plugging in or using this product. Failure to do so could result in electric shock,
fire, serious injury, or death.
Heating Indicator Light
& Remote Receiver
5
5
Heating Indicator Light