Replacing the operating panel cable
Figure 5: Removing the LEDs
Ê Extract the holder of the LED at the inside of the chassis and push the LED
out of the holder from the front side. Remove the second LED in the same
way.
Ê Disconnect the plug from the temperature sensor (see figure 8 on page 25).
Ê Release the cables from the cable clamps, pull them through the recesses
of the chassis.
Ê Disconnect the plug from the system board (connector Panel 1, see system
board foil D2530).
Ê Connect the new operating panel cable to the system board.
Ê Route the new operating panel cable as the old one.
Ê Push the two LEDs in their holders at the inside of the chassis.
Ê Insert the on/off button in its holder and fasten it with two screws.
Ê Hook the front cover into the right hand side (see figure 3 on page 20), close
the front cover and push it in the chassis until the locking levers engage.
Ê Close the server (for a detailed description see the Options Guide) and
connect the power plug.