Fujitsu fi-4860C Petunjuk Penggantian dan Pembersihan Bahan Habis Pakai - Halaman 5
Jelajahi secara online atau unduh pdf Petunjuk Penggantian dan Pembersihan Bahan Habis Pakai untuk Pemindai Fujitsu fi-4860C. Fujitsu fi-4860C 30 halaman. Production color scanner
Juga untuk Fujitsu fi-4860C: Manual Prosedur Instalasi (7 halaman), Manual Prosedur Instalasi (9 halaman), Prosedur Instalasi (3 halaman), Lembar Spesifikasi (2 halaman)
R
B
S
EPLACING THE
ACK
A defective or improperly installed Back Side Lamp can cause the "Back
Side Optical Alarm" message to be displayed on the Operator Panel of
the scanner. Vertical lines or bad image quality on the back scan can
also be caused by a defective Back Side Lamp.
•
Push the Blue Locking Tab
back and pull open the side
cover. The cover is on the
left side of the scanner.
•
Hold the Blue handle and pull
out the Back Side Lamp Unit.
•
Rotate the lamp a half turn
so that the 2 terminals on
each end of the lamp align
with the slot on the lamp
socket and remove the lamp
from the lamp unit.
•
Install the new lamp in the
lamp unit by inserting the
terminals of the lamp into the
socket and rotating the lamp
as shown to the right.
fi-4860C C
L
IDE
AMP
Clear Area
R
ONSUMABLE
EPLACEMENT AND
C
I
LEANING
NSTRUCTIONS
5