Dell PowerVault NX1950 Panduan Peningkatan - Halaman 13

Jelajahi secara online atau unduh pdf Panduan Peningkatan untuk Penyimpanan Dell PowerVault NX1950. Dell PowerVault NX1950 18 halaman. For vmware esx server software
Juga untuk Dell PowerVault NX1950: Panduan Penyebaran (34 halaman), Panduan Informasi Penting (26 halaman), Memulai (49 halaman), Panduan Instalasi dan Pemecahan Masalah (48 halaman), Panduan Penyebaran (38 halaman), Panduan Referensi (4 halaman), Menyiapkan (2 halaman), Menggunakan (2 halaman), Panduan Konfigurasi (11 halaman)

Dell PowerVault NX1950 Panduan Peningkatan
Select the desired highly available iSCSI instance from the drop-down
d
menu and click Next.
Click Finish. The Target is successfully created.
e
4 Move the volume to the desired highly available iSCSI instance:
Launch the Cluadmin interface and locate the volume that the
a
devices (.vhd files) are located on. The volume may be located in
Cluster Groups.
Select the volume, right-click, and select Change Groups.
b
Select one of the newly-created highly available iSCSI instances where
c
you want to move the volume.
A dialog box appears to confirm if you are changing groups. Click Yes
d
and click Yes again.
5 Import devices by performing the following:
Right-click the Devices icon in the Microsoft Management Console
a
and select Import Virtual Disk. Click Next.
Browse to the volume the .vhd files are located on. Select the .vhd file,
b
click OK.
Click Next and then click Finish.
c
Repeat step b and step c to import all .vhd files.
d
6 Create Virtual Disk-Target Associations by performing the following:
Right-click the Target and select Add existing virtual disk.
a
Select the virtual disk you want to add and click OK.
b
The virtual disk is associated to the Target and is ready for use.
c
However, the storage disks are not ready for use. To resume usage of the
storage disks from the Initiator:
Go to the Host or the Initiator and log on to the Targets that you
a
created.
Go to disk management and verify that the disk is accessible and is
b
displayed as Healthy. If the disk is not active, right-click on the
volumes and click Reactivate.
Configuring 3.1 Target
13