Juga untuk HP ProCurve 1600M: Lembar Spesifikasi (12 halaman), Baca Saya Terlebih Dahulu (8 halaman), Panduan Peninjau (27 halaman), Panduan Tambahan (2 halaman), Panduan Tambahan (2 halaman), Panduan Instalasi (36 halaman), Panduan Instalasi (28 halaman), Panduan Pengaturan Cepat (2 halaman), Panduan Pengaturan Cepat (4 halaman), Panduan Pengguna (8 halaman), Suplemen Manual (28 halaman), Baca Saya Terlebih Dahulu (16 halaman), Instalasi dan Penghapusan (2 halaman), Panduan Instalasi (12 halaman), Panduan Perencanaan dan Pelaksanaan (40 halaman), Petunjuk Pembongkaran Akhir Masa Pakai Produk (2 halaman), Panduan Instalasi (46 halaman), Panduan Diagnostik (2 halaman), Petunjuk Pembongkaran (2 halaman)

HP ProCurve 1600M Panduan Instalasi

Connectors

The ports on the 10/100-TX GL Module are compatible with the IEEE
I
802.3 10Base-T and 802.3u 100Base-TX standards and accept the 10 Mbps
or 100 Mbps cables listed below.
I
The ports on the 100/1000-T GL Module and the 100/1000-T Trans-
ceiver, which can be installed in the Gigabit Transceiver GL Module,
are compatible with the IEEE 802.3u 100Base-TX and IEEE 802.3ab
1000Base-T standards, and accept the 100 Mbps or 1000 Mbps cables listed
below. For 1000 Mbps operation, Category 5E twisted-pair cable is
recommended.
The port on the 100-FX SC Transceiver, which can be installed in the
I
Gigabit Transceiver GL Module, transmits at 1300 nm wavelength, and
is compatible with the IEEE 802.3u 100Base-FX standard. It accepts the
multimode fiber-optic cables for 100Base-FX described on the next page.
I
The port on the Gigabit-SX Transceiver, which can be installed in the
Gigabit Transceiver GL Module, transmits at 850 nm wavelength, and
is compatible with the IEEE 802.3z Gigabit-SX standard. It accepts the low
metal content, multimode fiber-optic cables for Gigabit-SX described on
the next page.
The port on the Gigabit-LX Transceiver, which can be installed in the
I
Gigabit Transceiver GL Module, transmits at 1300 nm wavelength, and
is compatible with the IEEE 802.3z Gigabit-LX standard. It accepts the low
metal content, single mode or multimode fiber-optic cables for
Gigabit-LX described on the next page.

Cables

Twisted-Pair
10 Mbps Operation
100 Mbps Operation
1000 Mbps Operation Category 5E 100-ohm differential UTP or STP cable,
Category 3, 4, or 5 100-ohm differential unshielded twisted-
pair (UTP) or shielded twisted-pair (STP) cable, complying
with IEEE 802.3 10Base-T specifications, fitted with RJ-45
connectors
Category 5 100-ohm differential UTP or STP cable,
complying with IEEE 802.3u 100Base-TX specifications,
fitted with RJ-45 connectors
complying with IEEE 802.3ab 1000Base-T specifications,
fitted with RJ-45 connectors
(please see "Note on 1000Base-T Cable Requirements",
below)