Display for magnetic band
This parameter together with the following allows the programming of the value on the display for
a certain displacement of the sensor. It means that is necessary to set the value which has to be
displayed corresponding to a displacement of the sensor on the magnetic band of 10mm.
The Factory value is
VISUAL
millimetres with decimal resolution.
The range allowed is from 0,0001 to 99999 with setting of decimal point position that is, after
programming of the last digit on the left, pressing key
key
it can be moved to the wanted position. Confirm with
Number of decimal digits
It is the number of decimal digits to visualize on the display, range allowed from 0 to 4.
Example: for every 10mm of linear displacement it is necessary to display 12.345 with only two
decimal places: Set
Keys opening mode
This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the
right stands for setting of key
the left stand for key
The values allowed are the following:
VALUE
0
1
2
3
4
5
6
7
8
* Delayed means that to activate the function (reset or preset), it is necessary to keep
/
pressed for approximately 3 s.
ENTER
RESET
Reset: reset function of the displayed value; after pressing
set to zero.
Preset: preset function of the displayed value; after pressing
becomes equal to the value in the
(when the digit on the right is set to 2).
Fast Preset: the fast setting of the displayed value on the display; after pressing
appears and pressing 2 times
and then confirm with
corrected often.
Origin change (correction of the displayed value for tool changes): with this function 3 different
origins (0,1,2) can be set and with
After setting 4 in the first digit on the right of the
Data: 13/01/16
=10.0, which is the necessary value to read the displacement in
=12,345 and
=2
, the digit in the middle stands for key
RESET
.
Not active
mm/inch conversion
Not active
Not active
Not active
Not active
Not active
Not active
Not active
parameter, which can be set immediately after
/
ENTER
RESET
/
). This function is useful when the displayed value must be
ENTER
RESET
/
ENTER
RESET
will blink the decimal pinpoint and with
RESET
Not active
abs/rel
measurement
Not active
Not active
Not active
Not active
Not active
Not active
Not active
ENTER
ENTER
it is possible to set the value directly (use
it is possible to switch from one origin to another.
parameter,
F7_ing.doc
.
while the last digit on
/
ENTER
RESET
Not active
Reset
Preset
Fast Preset
Change of origin
0,1,2
Offset
Fast Offset
Delayed reset *
(after 3s)
Delayed preset *
(after 3s)
/
, the displayed value is
RESET
/
, the displayed value
RESET
ENTER
will appear and after
F7
/
RESET
and
pag 4/12