ACU-RITE SENC 150 Petunjuk Manual - Halaman 6
Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Konverter Media ACU-RITE SENC 150. ACU-RITE SENC 150 12 halaman. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Juga untuk ACU-RITE SENC 150: Panduan Instalasi (8 halaman), Panduan Referensi (20 halaman), Panduan Instalasi (4 halaman), Panduan Instalasi (6 halaman)
3 Removing the encoder
Removing the reading head screws
1
Do not remove any mounting brackets unless it is completely
unavoidable.
Remove the two reading head mounting fasteners.
Removing the center support
Center
support
Remove the fastener from the center support if one is
present.
6
1
M4 x 25 mm SHCS low head
(8-32 x 5/8" SHCS low head)
(8-32 x 3/4" SHCS low head)
M6 x 25 mm
1
(1/4"-20 x 3/4" BHCS)
M6 flat washer
1
SENC 150 Reading Head Replacement Instructions
Removing the end hole or set screws
M6 x 25 mm
1
(1/4"-20 x 3/4" BHCS)
M6 flat washer
Remove the end hole mounting fasteners unless encoder is
spar mounted, then loosen the set screws and remove the
scale case from the spar.
Removing the end cap(s)
spring clip
The reading head can be removed from either end. The view
shown is for illustration only. Use caution not to lose the
spring clip during the end cap removal.
set screws
1