DIS Sensors QG40N Panduan Pengguna - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Beralih DIS Sensors QG40N. DIS Sensors QG40N 15 halaman. Tilt/acceleration switch (sil1 plc)
Juga untuk DIS Sensors QG40N: Panduan Pengguna (5 halaman), Panduan Pengguna & Keselamatan (6 halaman)

DIS Sensors QG40N Panduan Pengguna

Zero Adjustment

To eliminate mechanical offsets, a zero adjustment can be performed during the 1
power up the zeroing input is sensitive for a zeroing action.
Sequence:
1. Left input unconnected during power up for at least 0.5s
2. Switched/connect input to Gnd for at least 0.5s
3. Left unconnected again
4. Result: The sensor will set the current inclination position as 0°. The actual zeroing point is
where the input changes from Gnd to unconnected.
The maximum zeroing-range is specified in the datasheet. Horizontal mounting sensors have zeroing-
range-limit of ±5°, vertical mounting sensor can be zero-ed over full 360°.
The new 0° value will be stored in non-volatile memory (EEPROM).

Programmable Parameters (Tilt Switch Only)

Each switching output is pre-programmed to have certain parameters, these parameters can also be
changed by the customer with optional QG40N configurator.
DIS SENSORS BV
User Manual - QG40N Tilt/Acceleration Switch (SIL1 PLc) V2.0
Figure 3 - Configuration panel
minute after
st
9